CurvoStudio

Current model·Electromagnetic induction

Single-phase transformer

Observe how alternating magnetic flux transfers energy from the primary winding to the secondary winding.
Power off · Ready0.0 s / 15 s
Power off
Drag to rotate
Turns ratio0.1 N₂/N₁
Secondary voltage0 V
Secondary current0 A
Core flux density0 T

Induction experiment

Voltage and magnetic flux waveforms

Change turns, frequency and load to observe the induced secondary voltage and core flux.

Live winding valuesApply power to generate the curves
Primary and secondary voltageTwo AC cycles with individual normalized amplitudes
PrimarySecondary
010203040+10−1Time (ms)Normalized voltageApply power to generate the curves
Core magnetic flux densityFlux lags the applied voltage by approximately 90°
Bmax 0 T
010203040+10−1Time (ms)Flux densityApply power to generate the curves